研究尿流动力学导管F8,F6对于尿流率的影响

To study the influence of urinary flow mechanics catheter F8 and F6 on urinary flow rate

ES评分 0

DOI 10.12208/j.jmnm.20240123
刊名
Journal of Modern Nursing MedicineJPCNS
年,卷(期) 2024, 3(3)
作者
作者单位

芜湖市第二人民医院 安徽芜湖 ;

摘要
讨论并研究尿流动力学导管F8,F6对于尿流率的影响。方法 研究数据选取2023.4.18-2024.1.17共计108位患者尿动力检查结果,将使用F8导管的患者定义为F8组,共60位患者;将使用F6导管的患者定义为F6组,共48位患者。对比两组患者置管时疼痛、置管前患者组间最大尿流率、平均尿流率及尿流量及置管后患者组间最大尿流率、平均尿流率及尿流量。结果 ①F6组患者的VRS疼痛评分明显小于F8组,且F6组患者的无痛率明显高于F8组,上述数据对比差异均有统计学差异(P<0.05);②置管前患者组间最大尿流率、平均尿流率及尿流量比较无显著差异,无统计学意义(P>0.05);③相较于置管前,置管后患者组间最大尿流率、平均尿流率及尿流量有所改善。但与F8组患者相比,F6组患者的最大尿流率、平均尿流率及尿流量均较高,对比有统计学差异(P<0.05)。结论 尿流动力学导管F6在临床上具有减少患者置管时疼痛,改善患者最大尿流率、平均尿流率及尿流量的作用,有临床推广价值。
Abstract
Objective To discuss and study the effect of urinary flow mechanics catheter F8 and F6 on urinary flow rate. Methods A total of 108 patients were selected from 2023.4.18 to 2024.1.17 for the study data. Patients using F8 catheter were defined as F8 group, with a total of 60 patients. Patients using F6 catheters were defined as the F6 group, a total of 48 patients. Pain during catheterization, maximum, average and urinary flow rate between groups before catheterization and maximum, average and urinary flow rate between groups after catheterization were compared between the two groups. Results (1) The VRS pain score of F6 group was significantly lower than that of F8 group, and the pain-free rate of F6 group was significantly higher than that of F8 group, and the differences were statistically significant (P < 0.05). ② Before catheterization, there were no significant differences in the maximum urine flow rate, average urine flow rate and urine flow rate among groups (P > 0.05). (3) Compared with before and after catheterization, the maximum urine flow rate, average urine flow rate and urine flow rate were improved. However, compared with F8 group, the maximum urine flow rate, average urine flow rate and urine flow rate in F6 group were higher, and the difference was statistically significant (P < 0.05). Conclusion F6 can reduce the pain and improve the maximum urine flow rate, average urine flow rate and urine flow rate in patients with catheterization, and has the value of clinical promotion.
关键词
尿流动力学;导管F8;导管F6;尿流率;影响
KeyWord
urine flow mechanics; Catheter F8; Catheter F6; Urine flow rate; influence
基金项目
页码 73-76
  • 参考文献
  • 相关文献
  • 引用本文

王欣,孙燕*. 研究尿流动力学导管F8,F6对于尿流率的影响 [J]. 现代护理医学杂志. 2024; 3; (3). 73 - 76.

  • 文献评论

相关学者

相关机构