摘要
水是天然灭火剂,资源丰富,易于获取和储存,其自身和在灭火过程中对生态环境没有危害作用。消火栓是消防队员和建筑物内人员进行灭火的重要消防设施,作为现在主要灭火剂,根据火灾三要素可燃物、助燃物、达到温度的点火源,将达到温度的点火源降到着火点以下作为灭火原理。本文介绍消火栓设置场所及分类、室内湿式消火栓设计参数及要求等展开探讨。
Abstract
Water is a natural fire extinguishing agent, rich in resources, easy to obtain and store, and it is not harmful to the ecological environment in the process of fire extinguishing. Fire hydrant is an important fire fighting facility for firefighters and personnel in buildings to put out the fire. As the main fire extinguishing agent, the ignition source that reaches the temperature, and the ignition source that reaches the temperature is dropped below the ignition point as the fire extinguishing principle. This paper introduces the setting place and classification of fire hydrant, and the design parameters and requirements of indoor wet fire hydrant.
关键词
动压;静压;全压;充实水柱;火灾延续时间
KeyWord
Dynamic pressure, static pressure, full pressure, full water column, fire continuation time