Qcycle: A Field-Robust Metric for LiFePO4 Battery Degradation Monitoring in Sahelian Solar Irrigation Systems

Qcycle: A Field-Robust Metric for LiFePO4 Battery Degradation Monitoring in Sahelian Solar Irrigation Systems

ES评分 0

DOI 10.20900/jsr20260067
刊名
JSR
年,卷(期) 2026, 8(3)
作者
作者单位

Laboratoire Eaux, Hydro-Systèmes et Agriculture (LEHSA), Institut International d’Ingénierie de l’Eau et de l’Environnement (Institut 2iE), Rue de la Science, Ouagadougou 01 BP 594, Burkina FasoLaboratoire Énergies Renouvelables et Efficacité Énergétique (LabEREE), Institut International d’Ingénierie de l’Eau et de l’Environnement (Institut 2iE), Rue de la Science, Ouagadougou 01 BP 594

摘要
Solar-powered irrigation is expanding across the Sahel, yet a lack of field-compatible health metrics for LiFePO4 batteries limits predictive maintenance in decentralized systems. Coulombic Efficiency (CE) is unreliable under natural temperature and humidity fluctuations, thus masking early degradation. This study introduces Qcycle, the total capacity per charge-discharge cycle (QC + QD), and validates its robustness relative to CE under Sahelian semi-field conditions. Four 280 Ah LiFePO4 cells were cycled over five months (May–September 2022) in Kamboinsé, Burkina Faso, spanning dry and rainy seasons. Two regimes represented agricultural use: rapid 24-h cycles (146 total) and slow 96-h cycles (35 total). While CE oscillated erratically, Qcycle revealed consistent exponential capacity fade. Nonlinear regression yielded high goodness-of-fit values (R2 = 0.97 to 0.99), demonstrating the ability of Qcycle to consistently capture the observed degradation trend across the tested cells and cycling regimes. Qcycle provides a practical, instrumentation-tolerant alternative to CE for decentralized solar irrigation, supporting predictive maintenance in the water-energy-food nexus and advancing SDG 7 targets.
Abstract
Solar-powered irrigation is expanding across the Sahel, yet a lack of field-compatible health metrics for LiFePO4 batteries limits predictive maintenance in decentralized systems. Coulombic Efficiency (CE) is unreliable under natural temperature and humidity fluctuations, thus masking early degradation. This study introduces Qcycle, the total capacity per charge-discharge cycle (QC + QD), and validates its robustness relative to CE under Sahelian semi-field conditions. Four 280 Ah LiFePO4 cells were cycled over five months (May–September 2022) in Kamboinsé, Burkina Faso, spanning dry and rainy seasons. Two regimes represented agricultural use: rapid 24-h cycles (146 total) and slow 96-h cycles (35 total). While CE oscillated erratically, Qcycle revealed consistent exponential capacity fade. Nonlinear regression yielded high goodness-of-fit values (R2 = 0.97 to 0.99), demonstrating the ability of Qcycle to consistently capture the observed degradation trend across the tested cells and cycling regimes. Qcycle provides a practical, instrumentation-tolerant alternative to CE for decentralized solar irrigation, supporting predictive maintenance in the water-energy-food nexus and advancing SDG 7 targets.
关键词
battery health monitoring; LiFePO4 degradation; Qcycle metric; Sahelian climate; solar irrigation; water–energy–food nexus
KeyWord
battery health monitoring; LiFePO4 degradation; Qcycle metric; Sahelian climate; solar irrigation; water–energy–food nexus
基金项目
页码 -
  • 参考文献
  • 相关文献
  • 引用本文

Amadou Keïta, Daniel Yamegueu, Djim Doumbe Damba, Sodiya Keïta. Qcycle: A Field-Robust Metric for LiFePO4 Battery Degradation Monitoring in Sahelian Solar Irrigation Systems [J]. Journal of Sustainability Research. 2026; 8; (3). - .

  • 文献评论

相关学者

相关机构