地电阻率直流和交流观测对成都中心站地磁记录的干扰分析

Interference Analysis of DC and AC Geoelectrical Resistivity Observations on Geomagnetic Records at Chengdu Earthquake Monitoring Center Station

ES评分 0

DOI 10.14075/j.jgg.2024.09.439
刊名
Journal of Geodesy and Geodynamics
年,卷(期) 2025, 45(9)
作者
作者单位

1 四川省地震局成都地震监测中心站,成都市郫都区一环路西南段136号,611730

摘要
设置不同的供电参数对成都地震监测中心站并行运行的地电阻率直流和交流观测系统开展实验,分析总结不同地电阻率观测系统在测量时对同台地磁记录产生的干扰特征。结果表明,地电阻率直流观测对地磁记录造成的干扰呈正、反向大幅度方波形态,其输出电流幅值与干扰幅度呈正相关;地电阻率交流观测对地磁记录造成的干扰呈大幅度正弦波形态,在输出电流频率为1~10 Hz、输出电流幅值为0.1~0.5 A时不会对地磁记录产生干扰。此外,结合地电阻率交流观测实验结果模拟FGM-01磁通门磁力仪的幅频特性曲线,该曲线符合低通滤波器的频响特性。
Abstract
We conduct experiments on the parallel operation of DC and AC geoelectrical resistivity observation systems at Chengdu earthquake monitoring center station by setting different power supply parameters, and summarize the interference characteristics of different geoelectrical resistivity observation systems on geomagnetic records at the same station. The results show that the interference caused by DC geoelectrical resistivity observation on geomagnetic records is in the form of positive and negative large amplitude square waves, and the output current amplitude is positively correlated with the interference amplitude. The interference caused by AC geoelectrical resistivity observation on geomagnetic records is in the form of large amplitude sine waves, and will not interfere geomagnetic records when the output current frequency is 1-10 Hz and the output current amplitude is 0.1-0.5 A. In addition, based on the experimental results of AC geoelectrical resistivity observation, we simulate the amplitude frequency characteristic curve of the FGM-01 fluxgate magnetometer, which conforms to the frequency response characteristics of a low-pass filter.
关键词
地电阻率直流和交流观测; 地磁观测; 干扰分析
KeyWord
DC and AC geoelectrical resistivity observation; geomagnetic observation; interference analysis
基金项目
页码 944-949
  • 参考文献
  • 相关文献
  • 引用本文

李雪浩, 李国超, 李贵元, 龚康, 何思源. 地电阻率直流和交流观测对成都中心站地磁记录的干扰分析 [J]. 大地测量与地球动力学. 2025; 45; (9). 944 - 949.